: Electron backscatter at interfaces between dissimilar media can affect dosimetry and should be taken into consideration in radiotherapy and in radiobiology experiments. Backscatter dose perturbations depend upon factors such as electron energy, medium atomic number (Z), and distance from the interface. This study quantifies the backscatter dose factor (BSDF) for electron point sources of energy between 0.1 to 3 MeV in water at the interface with scattering materials ranging in Z from (13)Al to (79)Au. A Monte Carlo code that performs dose calculations for monoenergetic and continuous-spectrum electron sources was developed using EGSnrc transport routines. The BSDF was quantified in a parallel layers geometry (BSDF(1D)) and three-dimensional voxel geometry (BSDF(3D)). The BSDF(1D) near the interface increased up to 52% with decreasing energy from 3 to 0.1 MeV and increasing Z from 13 to 79. The analysis of the BSDF(3D) showed a significant dependence of the scattered electron angular distribution on Z and energy, with a decrease in isotropy going from high to low Z. This effect proves the importance of considering the correct geometry when quantifying the BSDF for electron sources, especially when the dimensions of the relevant dose-collecting volume are comparable with the CSDA range of the source.

Backscatter and dose perturbations for low- to medium-energy electron point sources at the interface between materials with different atomic numbers

Buffa, Francesca M
Investigation
;
2004

Abstract

: Electron backscatter at interfaces between dissimilar media can affect dosimetry and should be taken into consideration in radiotherapy and in radiobiology experiments. Backscatter dose perturbations depend upon factors such as electron energy, medium atomic number (Z), and distance from the interface. This study quantifies the backscatter dose factor (BSDF) for electron point sources of energy between 0.1 to 3 MeV in water at the interface with scattering materials ranging in Z from (13)Al to (79)Au. A Monte Carlo code that performs dose calculations for monoenergetic and continuous-spectrum electron sources was developed using EGSnrc transport routines. The BSDF was quantified in a parallel layers geometry (BSDF(1D)) and three-dimensional voxel geometry (BSDF(3D)). The BSDF(1D) near the interface increased up to 52% with decreasing energy from 3 to 0.1 MeV and increasing Z from 13 to 79. The analysis of the BSDF(3D) showed a significant dependence of the scattered electron angular distribution on Z and energy, with a decrease in isotropy going from high to low Z. This effect proves the importance of considering the correct geometry when quantifying the BSDF for electron sources, especially when the dimensions of the relevant dose-collecting volume are comparable with the CSDA range of the source.
2004
Buffa, Francesca M; Verhaegen, Frank
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11565/4061976
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact