The detection of pneumococcal IgG antibodies is helpful for the evaluation of response to pneumococcal vaccination and need for revaccination. Results generated by the clinical assay which is currently used, in which the 23 valent polysaccharide vaccine is the antigen, were compared to those obtained by a capsular polysaccharide serotype-specific assay that measures IgG antibodies to 9 common serotypes causing invasive disease. Discrepancies in 21/47 (45%) of the results were observed in a direct comparison between the two assays. In each case a positive titre was obtained on the clinical assay but IgG levels on the serotype-specific assay were below the putative protective level of 0.2 μg/ml for at least one of the 9 serotypes assayed. The generation of false positives by the current clinical assay is due to its lack of specificity. Antibodies to C-polysaccharide and all of the 23 serotypes included in the pneumococcal polysaccharide vaccine are incorporated into the final titre whereas the serotype-specific assay adsorbs out noncapsular polysaccharide antibodies. The discrepancies between the two assays highlight the importance of standardized assays that measure putative correlates of protection and demonstrate the need to re-evaluate the current clinical assay. A tool that allows the interpretation of the results of the serotype-specific assay is provided and its potential for assessing individual susceptibility levels to vaccine preventable pneumococcal infection is discussed.

Measurement and interpretation of pneumococcal IgG levels for clinical management

Melegaro, A;
2003

Abstract

The detection of pneumococcal IgG antibodies is helpful for the evaluation of response to pneumococcal vaccination and need for revaccination. Results generated by the clinical assay which is currently used, in which the 23 valent polysaccharide vaccine is the antigen, were compared to those obtained by a capsular polysaccharide serotype-specific assay that measures IgG antibodies to 9 common serotypes causing invasive disease. Discrepancies in 21/47 (45%) of the results were observed in a direct comparison between the two assays. In each case a positive titre was obtained on the clinical assay but IgG levels on the serotype-specific assay were below the putative protective level of 0.2 μg/ml for at least one of the 9 serotypes assayed. The generation of false positives by the current clinical assay is due to its lack of specificity. Antibodies to C-polysaccharide and all of the 23 serotypes included in the pneumococcal polysaccharide vaccine are incorporated into the final titre whereas the serotype-specific assay adsorbs out noncapsular polysaccharide antibodies. The discrepancies between the two assays highlight the importance of standardized assays that measure putative correlates of protection and demonstrate the need to re-evaluate the current clinical assay. A tool that allows the interpretation of the results of the serotype-specific assay is provided and its potential for assessing individual susceptibility levels to vaccine preventable pneumococcal infection is discussed.
2003
Balmer, P; North, J; Baxter, D; Stanford, E; Melegaro, A; Kaczmarski, Eb; Miller, E; Borrow, R
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11565/3775112
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 32
social impact